Back To Index  <<  Back To Templates

ref Template  Laboratory Performer

Id 1.3.6.1.4.1.19376.1.3.3.1.7 ref (aus Repository: elgabbr-) Gültigkeit gültig ab 2014‑05‑26
Status active Aktiv Versions-Label
Name LaboratoryPerformer Anzeigename Laboratory Performer
Beschreibung
en-US Laboratory Performers SHALL be recorded as performers in the CDA Header as well as in the structured body. Documentation of laboratory performers MAY be done in multiple levels of the document to reflect performance scope. In the case where there is a single Laboratory Performer, this entity SHALL be documented in CDA header as shown. In the case where multiple Laboratory Performers participated in the lab testing process, they SHALL be documented in the structuredBody at the observation level. These performers SHALL conform to the General Constraints found in HL7 CRS: 2.1.1 with respect to the requirements for name, address, telephone numbers and other contact information.
This module is out of the XDS-Lab Specification and documented there in a <performer> element. This module does not change requirements stated in that specification but is structured as a module to ensure consistent content representation and re-usability.
Kontext Geschwisterknoten des Template-Element mit Id 1.3.6.1.4.1.19376.1.3.3.1.7
Klassifikation CDA Header Level Template
Offen/Geschlossen Offen (auch andere als die definierten Elemente sind erlaubt)
Benutzt von / Benutzt
Benutzt von 8 Templates, Benutzt 2 Templates
Benutzt von Template-Id als Name Version
1.2.40.0.34.11.4 Containment Laborbefund 2015‑09‑24
1.2.40.0.34.11.10003 link ELGA CDA Dokument Laborbefund 2013‑11‑07
1.2.40.0.34.11.4 Containment Laborbefund 2015‑02‑02
1.2.40.0.34.11.4 Containment Laborbefund 2014‑12‑06
1.2.40.0.34.11.4 Containment Laborbefund 2014‑03‑25
1.2.40.0.34.11.5 Containment Befund Bildgebende Diagnostik 2014‑11‑20
1.2.40.0.34.11.5 Containment Befund Bildgebende Diagnostik 2014‑03‑25
1.3.6.1.4.1.19376.1.3.1.6 Containment Laborergebnisse (Laboratory Observation) 2014‑03‑04
Benutzt Template-Id als Name Version
1.2.40.0.34.11.90001 Inklusion PersonElements DYNAMIC
1.2.40.0.34.11.90002 Inklusion OrganizationElements DYNAMIC
Beispiel
Beispiel
<performer typeCode="PRF">
  <templateId root="1.3.6.1.4.1.19376.1.3.3.1.7"/>
  <assignedEntity>
    <id extension="rm83747" root="1.3.6.1.4.1.19376.1.3.4"/>
    <addr>
      <streetAddressLine>7000 Hosptial Drive        7000 Hosptial Drive</streetAddressLine>      <city>Chicago        Chicago</city>      <state>IL        IL</state>      <postalCode>60622        60622</postalCode>      <country>USA        USA</country>    </addr>
    <telecom value="tel:312-555-5555"/>
    <assignedPerson>
      <name>
        <family>Trenton          Trenton</family>        <given>Douglas          Douglas</given>        <prefix>Dr.          Dr.</prefix>      </name>
    </assignedPerson>
    <representedOrganization>
      <id extension="rm83747" root="1.3.6.1.4.1.19376.1.3.4"/>
      <name>PRF Hospital Laboratory        PRF Hospital Laboratory</name>      <telecom value="tel:312-555-5555"/>
      <addr>
        <streetAddressLine>7000 Hosptial Drive          7000 Hosptial Drive</streetAddressLine>        <city>Chicago          Chicago</city>        <state>IL          IL</state>        <postalCode>60622          60622</postalCode>        <country>USA          USA</country>      </addr>
    </representedOrganization>
  </assignedEntity>
</performer>
Item DT Kard Konf Beschreibung Label
hl7:templateId
1 … 1 M (LaboratoryPerformer)
treetree @root
1 … 1 F 1.3.6.1.4.1.19376.1.3.3.1.7
hl7:time
IVL_TS 1 … 1 M (LaboratoryPerformer)
hl7:assignedEntity
1 … 1 M (LaboratoryPerformer)
treetree hl7:id
II 1 … 1 R (LaboratoryPerformer)
treetree hl7:code
CE 0 … 1 R (LaboratoryPerformer)
  Beispiel <code code="E" codeSystem="2.16.840.1.113883.2.16.1.4.9" codeSystemName="HL7.at.Laborkennzeichnung" displayName="EXTERN"/>
treetree hl7:addr
AD 1 … 1 M (LaboratoryPerformer)
treetree hl7:telecom
TEL.AT 1 … * M (LaboratoryPerformer)
Auswahl 1 … 
Angabe von Personenname oder Organisationsname ist verpflichtend.
Elemente in der Auswahl:
  • hl7:assignedPerson
  • hl7:representedOrganization
treeblank treetree hl7:assignedPerson
 … 1 (LaboratoryPerformer)
Eingefügt von 1.2.40.0.34.11.90001 PersonElements (DYNAMIC)
treeblank treeblank treetree @classCode
0 … 1 F PSN
treeblank treeblank treetree @determinerCode
0 … 1 F INSTANCE
treeblank treeblank treetree hl7:name
PN 1 … 1 (LaboratoryPerformer)
treeblank treetree hl7:representedOrganization
 … 1 (LaboratoryPerformer)
Eingefügt von 1.2.40.0.34.11.90002 OrganizationElements (DYNAMIC)
treeblank treeblank treetree @classCode
0 … 1 F ORG
treeblank treeblank treetree @determinerCode
0 … 1 F INSTANCE
treeblank treeblank treetree hl7:id
II 0 … * (LaboratoryPerformer)
treeblank treeblank treetree hl7:name
ON 1 … 1 (LaboratoryPerformer)
treeblank treeblank treetree hl7:telecom
TEL.AT 0 … * (LaboratoryPerformer)
treeblank treeblank treetree hl7:addr
AD 0 … 1 (LaboratoryPerformer)